Frameless wall cladding ZIPS III-ULTRA
Thickness: 55 mm
ΔRw ≈ 18 dB
When applied?
- If you need maximum effect with the smallest thickness.
- Saves from noises of average volume - conversations, TV, barking dogs, crying children.
- The construction is recommended for gypsum, brick and concrete walls, partitions, as well as reinforced concrete floors.
Overview
Sound-insulating panel system ZIPS III-Ultra comprises the ZIPS III-Ultra panels and the finishing plasterboard. Sound-insulating sandwich panels ZIPS III-Ultra have proved to be the most efficient in terms of their thickness/result ratio. They are used to increase the sound insulation of single-layer structures like gypsum, brick and concrete walls, partitions, as well as reinforced concrete floors in the construction and reconstruction of any type of buildings. Sound-insulating panel system ZIPS III-Ultra is effective against most household noises: speech, crying, barking dogs, medium-power TV and radio equipment, household impact noise.Sound-insulating panel system ZIPS III-Ultra consists of 42.5 mm thick ZIPS III-Ultra sandwich panels, and 12.5 mm special finishing plasterboard.
Excessively protruding Ultrakustik TAPE is cut flush with the finishing layer of gypsum plasterboard sheets. Seams are filled with Ultrakustik VS vibroacoustic silicone sealant.
Other constructions in this section
You can calculate the approximate estimate of sound insulation in your case. To do this, it is enough to enter the surface area that is supposed to be isolated. The estimate is calculated with a 5% margin, as well as taking into account rounding to whole packages. Please note that the estimate is approximate, since it does not take into account the individual characteristics of your premises.
Specialized sound insulation materials:
Specialized accessories:
General construction materials:
- ZIPS-III-Ultra panels are attached to the wall only through the existing vibration units using plastic dowels.
- If the panel is installed as a whole (without cutting) on an insulated wall, then installation is carried out using only six attachment points, the central attachment points are not used.
- The ends of the sandwich-panels must adjoin the side walls and the ceiling through two layers of Ultrakustik TAPE vibration damping spacer. The tape is glued and fixed with Ultrakustik-Sealant.
- The head of the screw should be screwed into the vibration unit no deeper than 1-2 mm from the level of the front side of the panel.
- If the panel is cut, then all available attachment points are used for installation. Cuttings less than 250 mm are not used in the installation.
- Upon completion of installation, the joints between the sandwich-panels are treated with Ultrakustik VS The finishing layer of gypsum plasterboard sheets 12.5 mm thick is fixed to the resulting surface. Sheets must adjoin to the adjacent surfaces through 2 layers of Ultrakustik TAPE vibration damping spacer as well.
- Excessively protruding Ultrakustik TAPE is cut flush with the finishing layer of gypsum plasterboard sheets. Seams are filled with Ultrakustik VS vibroacoustic silicone sealant.