Sound insulation of the floor

Order by:
  • thickness
  • ΔRw
    ΔRw – the index of ADDITIONAL sound insulation of airborne noise provided by the construction
  • ΔLnw
    ΔLnw – the index of ADDITIONAL sound insulation of impact noise provided by the construction
Hydro-soundproofing floor with the use of Ultrakustik-100 Hydro

When applied?

  • If there is a need to reduce noise from footsteps and attain a reliable waterproofing. Most often used in wet premises.
Thickness: 65 mm
ΔLnw ≈ 24 dB
Soundproofing floor with the use of Ultrakustik Floor Plast

When applied?

  • If you need to make soundproofing and level the floors.
  • When loud noise from the TV, radio and conversations, as well as footsteps interferes.
Thickness: 80 mm
ΔRw ≈ 9 dB
ΔLnw ≈ 28 dB
Under the finish coating with the use of ZIPS Floor Modul

When applied?

  • When loud noise from the TV, radio and conversations interferes.
  • To reduce impact noise when wet processes are unacceptable.
Thickness: 110 mm
ΔRw ≈ 9 dB
ΔLnw ≈ 32 dB
Under the finish coating with the use of ZIPS Floor Vector

When applied?

  • To reduce medium intensity noise from neighbors below.
  • To reduce impact noise when wet processes are unacceptable.
Thickness: 85 mm
ΔRw ≈ 8 dB
ΔLnw ≈ 28 dB