Frameless wall cladding ZIPS Modul
Thickness: 83 mm
ΔRw ≈ 18 dB
When applied?
- If the noise of medium volume from conversations, TV, barking dogs and other household sources interferes.
- The structure is recommended for gypsum, brick and concrete walls, partitions, as well as reinforced concrete floors.
Overview
ZIPS Modul sound-insulating panel system consists of the ZIPS Modul panels and the finishing plasterboard layer. They are used to improve sound insulation in apartments, cottages, and commercial facilities such as cafes, restaurants, etc.
ZIPS Modul panels are mounted directly onto the surface of single-layer enclosing structures: walls and ceilings, without using a frame. ZIPS Modul panels are attached to walls and ceiling by special vibration joints that prevent transmission of noise from insulated surface to external surface of the structure. The use of lightweight sound-absorbing and heavy sound-reflecting layers in the panels, as well as the absence of rigid connections in the form of framework, ensures efficient reduction of transmitted sound waves.
Other constructions in this section
You can calculate the approximate estimate of sound insulation in your case. To do this, it is enough to enter the surface area that is supposed to be isolated. The estimate is calculated with a 5% margin, as well as taking into account rounding to whole packages. Please note that the estimate is approximate, since it does not take into account the individual characteristics of your premises.
Specialized sound insulation materials:
Specialized accessories:
General construction materials:
ZIPS-Modul panels are attached to the wall only through the existing vibrating units using plastic dowels.
The ends of the sandwich panels must adjoin the side walls and the ceiling through two layers of Ultrakustik TAPE vibration insulating tape. The tape is glued and fixed with Ultrakustik VS.
If the panel is installed as a whole (without cutting) on an insulated wall, then installation is carried out using only six fastening points, the central fastening points are not used.
The head of the screw should be screwed into the vibration unit no deeper than 1-2 mm from the level of the front side of the panel.
If the panel is cut, then all available attachment points are used for installation. Cuttings less than 250 mm are not used in the installation.
Upon completion of installation, the joints between the sandwich panels are treated with Ultrakustik VS sealant. The finishing layer of gypsum plasterboard sheets 12.5 mm thick is fixed to the resulting surface. Sheets must adjoin to the adjacent surfaces through 2 layers of Ultrakustik TAPE vibration insulating spacer as well.
Excessively protruding Ultrakustik TAPE is cut flush with the finishing layer of gypsum plasterboard sheets. Seams are filled with Ultrakustik VS vibroacoustic silicone sealant.